Ziehm Vision RFD Hybrid Edition


The Comprehensive Mobile Hybrid Solution

An aging population is creating an increasing demand for cardiovascular surgery. The Ziehm Vision RFD Hybrid Edition1 is a powerful 25 kW mobile C-arm that comes with CMOS technology for even better image quality in challenging procedures such as these. By taking OR flexibility and clinical capabilities to the next level, The Ziehm Vision RFD Hybrid Edition is a valuable contribution to any clinic's competitiveness and financial performance. Requiring zero modifications to existing ORs, this mobile, feature-rich hybrid solution is ready to go - anytime, anywhere.

The system Ziehm Vision RFD Hybrid Edition is now available in the CMOSline2,3 premium edition. All CMOSline systems come with a Ziehm Imaging CMOS detector and the groundbreaking dose reduction technology Beam Filtration4. This combination allows for excellent image quality with a lower dose.

Features


Ensure the best performance of your
C-arm

Customer Service

AT A GLANCE

Imaging technology
CMOS, flat-panel, 21 cm x 21 cm / 31 cm x 31 cm
a-Si, flat-panel, 30 cm x 30 cm
Detector resolution
CMOS: 2 k x 2 k / 3 k x 3 k
a-Si: 1.5 k x 1.5 k
Power Generator
25 kW, pulsed monoblock generator
Ziehm Usability Concept
available
SmartDose
available
Advanced Active Cooling (AAC)
available
Orbital movement
165 degrees
Motorization
Full control of the 4 motorized axes

1Ziehm Vision RFD Hybrid Edition represents a group of optional hardware and software that creates an option package on the device named Ziehm Vision RFD.

2CMOSline represents a system configuration that is based on a Ziehm Imaging CMOS flat-panel detector.

3This product/feature might not be commercially available in all countries. Due to regulatory reasons their future availability cannot be guaranteed. Please contact Ziehm Imaging for detailed information.

4The technology Beam Filtration reduces dose exposure for Ziehm Imaging flat-detector systems in comparison with conventional filtration techniques. Data on File. Results may vary.

5In clinical practice, the use of SmartDose may reduce patient dose depending on the clinical task, patient size, anatomical location, and clinical practice. A consultation with a radiologist and a physicist should be made to determine the appropriate dose to obtain diagnostic image quality for the particular clinical task.

6Gosch D. et al. “Influence of grid and ODDC on radiation exposure and image quality using mobile C-arms – First results”, RöFo, 09/07

7The Usability Concept includes a variety of hard- and software features. Due to regulatory reasons the availability of each feature may vary. Please contact your local Ziehm Imaging sales representative for detailed information.